id Name Unit Comment
-1 Unknown unk Unknown register type
1 Energy consumption kWh The energy consumed during a specified interval
2 Accumulated energy consumption kWh The total energy consumed since the meter activation timestamp
3 Energy production kWh The energy produced during a specified interval
4 Accumulated energy production kWh The total energy produced since the meter activation timestamp
5 Voltage V The difference in electric potential over the meter
6 Electrical current A The flow of current trough the meter
7 Active power consumption kW The active power consumed by the device
8 Reactive power consumption var The reactive power consumed by the device
9 Liquid consumption m3 The liquid consumption measured by the device during a specified interval
10 Accumulated liquid consumption m3 The total liquid volume consumed since the meter was activated
11 Temperature C The ambient temperature in °C
12 Relative humidity % Relative humidity (RH) refers to the moisture content (i.e., water vapor) of the atmosphere, expressed as a percentage of the amount of moisture that can be retained by the atmosphere (moisture-holding capacity) at a given temperature and pressure without condensation.
13 Battery level % The remaining battery charge of the underlying device in percentage
14 Fluid flow m3/h The fluid flow measured at a specific timestamp
15 Supply temperature C The supply temperature of a thermal energy system
16 Return temperature C The return temperature of a thermal energy system
17 Phase L1 current A The current in the electrical phase L1
18 Phase L2 current A The current in the electrical phase L2
19 Phase L3 current A The current in the electrical phase L3
20 Phase L1 voltage V The voltage in the electrical phase L1
21 Phase L2 voltage V The voltage in the electrical phase L2
22 Phase L3 voltage V The voltage in the electrical phase L3
23 L1-L2 line voltage V The difference in electrical potential between electrical phases L1 and L2
24 L2-L3 line voltage V The difference in electrical potential between electrical phases L2 and L3
25 L3-L1 line voltage V The difference in electrical potential between electrical phases L3 and L1
26 Active power production kW The active power produced by the device
27 Reactive power production var The reactive power produced by the device
28 Fan speed N/A Fan speed
128 Temperature setpoint C Setpoint for temperature control
129 Temperature min setpoint C Setpoint for min temperature
130 Temperature mid setpoint C Setpoint for mid temperature
131 Temperature max setpoint C Setpoint for max temperature
132 Fan speed setpoint N/A Setpoint for fan speed
133 Fan speed min setpoint N/A Setpoint for min fan speed
134 Fan speed mid setpoint N/A Setpoint for mid fan speed
135 Fan speed max setpoint N/A Setpoint for max fan speed